0731-84284278

美 Meriam M3500第七代名将工業压强压力变送器

品牌:压力差表
品脾:
技术参数:

简介:美国 Meriam M3500 系列新一代工业压力变送器的详细介绍 M3500 系列新一代工业压力变送器 Pressure ranges: Lower Sensor Limit (LSL) to Upper Sensor Limit (US...

  • 产品介绍

M3500 系列新一代工业压力变送器
美国 Meriam M3500 系列新一代工业压力变送器的详细介绍
M3500 系列新一代工业压力变送器
Pressure ranges: Lower Sensor Limit (LSL) to Upper Sensor Limit (USL) listed below:
Differential [DI]: 0-1, 0-5, 0-15, 0-30, 0-100, 0-300, 0-500 PSID
Gauge [GI]:  0-15, 0-30, 0-50, 0-100, 0-300, 0-500, 0-1000, 0-3000 PSIG
Compound [CI] (PSIG): -15 to +15, -15 to +30, -15 to +50, -15 to +100, -15 to 300,
                                                -15 to +500, -15 to +1000, -15 to + 3000 PSIG
Absolute [AI]: 0-17.4, 0-38.7, 0-100, 0-1000 PSIA
Measurement Accuracy:  ±0.025% FS including all effects of linearity, hysteresis, repeatability and temperature from -20º to +50º C (-4º to +122º F)
Output (mA / V) accuracy: ±0.05% FS including all effects of linearity, hysteresis, repeatability and temperature from -20º to +50º C (-4º to +122º F)
Traceability: NIST traceable certification is standard
Analog Span Limit
DI ,GI, and CI types: 4:1 turndown from Upper Sensor Limit (USL)
AI: 2:1 turndown from Upper Sensor Limit (USL)
Overpressure Limits
DI:  1000 PSI common mode pressure
     P1 (High) side only: 3x range
     P2 (Low) side only: 3x range or 150 PSI, whichever is less
GI, CI, AI: 2x Full Scale
Differential Pressure Sensors
Static Pressure effect on zero: worst case 0.025% URL per 100 PSI. See User’s Manual for further details. This    effect can be corrected by zeroing the unit at the desired static pressure using an equalizing manifold.
Static Pressure effect on accuracy: worst case 0.1% URL per 100 PSI. See User’s Manual for details.
Orientation effect on zero: installation orientations different from factory calibration orientation may cause zero offsets up to 1% F.S. on some ranges.  Zero the M3500 in its installed position to eliminate zero offset.
Temperature Specifications   
          Operating Range:      -20º to +70° C (-4º to +158° F)
          Calibrated Range:     -20º to +50º C (-4º to +122º F)
              Storage Range:     -20º to +70° C (-20º to +158° F)
Temperature effect on output accuracy when above 50º C: standard accuracy +0.005% F.S. per ºC
Wetted Parts
    DI: 316L SS and Viton® (Kalrez available, consult factory for other o-ring
               material options)
    GI, CI, AI: 316L SS
Damping: Exponential damping with user adjustable time constant, 0 (Off) to 60 seconds
Sensor Zero: push button or HART®. Differential Pressure units can have zero fully elevated
                    or suppressed within the Lower and Upper Sensor Limit
Trims: analog trims, lower sensor trim and upper sensor trim are available via push button or HART®
mA output failure modes:
    Saturation values: 3.9 mA and 20.48 mA
    Failure values: 3.8 mA and 22.5 mA
Internal electronics temperature measurement available from display and via HART®.
Pressure Applications: differential, vacuum, compound, gauge or absolute
Pressure Units: 
PSI, inches of Water (ref. 20°C, 60°F and 4°C), kg/cm2, MPa, kPa,  Pa,  mbar, bar, cm of Water (ref. 20°C and 4°C), ft of Water (ref. 20°C, 60°F and 4°C), inches of Mercury @ 0°C,  mm of Mercury @0°C, oz/sq in, User defined unit (linear scaling constant from PSI)
Flow applications: Square Root (Sq. Rt.) or Laminar Flow Element (Classical B & C method) applications
Flow Units:
    Volume flow: m3, l (liters), yd3, ft3, in3, US gal (US gallons), I gal (Imperial gallons),bbl (barrel), User defined unit
    Mass flow: lbs, tons, kg, STon (Short Tons), LTon (Long Tons), User defined unit
    Time: seconds, minutes, hours, days
Flow related features:
    Low Flow cut off value
    Total flow since last reset
    Reset total flow register to zero
    Total non-resettable flow
Level applications: Supports direct head and bubbler type level calculations for linear tanks (vertical), non-linear tanks (horizontal, cylindrical [flat or dished ends] and spherical), and custom strapping tables.
Level Units:
Height: yards, feet, inches, meters, centimeters, millimeters
Liquid volume: cubic inches, US gallons, Imperial gallon, barrels, cubic meters, liters, cubic yards, cubic feet,   percent, user defined unit (linear scaling constant)
Liquid mass: pounds, tons, kilograms, Short Tons, Long Tons, percent, user defined             unit (linear scaling constant)     
Enclosure:     Aluminum casting, designed to
                    NEMA 4 requirements
                    Front and rear caps secured with set screws
Dimensions:   5.12” L x 3.56” Dia. x 4.57” H
Weight:         2.7 – 3.0 lbs
Conduit connections: ½” NPT (female), 2 ea., 1 permanent plug included
Pressure Manifold:
     Material: 316L SS
     Pressure connection(s): 1/8” NPT (female) for all pressure sensor types
     1/8” NPT(M) x ¼” NPT(F) 316L SS adapter(s) are included
Differential Pressure models are available with a standard 2 port manifold or optional 4 port manifold with bleed/flushing connections and plugs (5/16 – 24 SAE/MS J1926)
Display – 2 line LCD
    Upper line for up to 5 numeric characters
    Lower line for up to 6 alphanumeric characters
    Update rate: 3x per second
    Floating decimal point   
Display orientation to be specified with order:
  Standard, Clockwise [90º], Reverse [180º], or
  Counterclockwise [270º] orientation
Name plate:
The name plate on top of the M3500 provides model and serial numbers plus other specifications. Loosen the lower right screw and slide to access the keypad.                        
Keypad:
Located under the name plate, the keypad consists of 4 arrow keys used for manual programming and trim adjustments (sensor zero, lower sensor trim, upper   sensor trim and analog trims).
Electrical connections:
    Six (6) position terminal block for
    •  Loop Power & Communication (2- wire)
    •  Two opto-coupler SPST switches
    •  1.3 mm diameter holes suitable for 16 – 25
        gauge solid or stranded wire
    Case grounding screw
    Test tabs for mA output
    Comm tabs for HART® communications
Power:  16 – 45 V DC
Load Curve:   Maximum Loop Resistance = (50 * Power Supply Voltage) - 800
Note: HART communication requires a minimum loop resistance of 250Ω (21V DC)
Outputs:
4 – 20 mA (2-wire)
HART® digital protocol
Two each, solid state opto-coupler SPST switches  
Rating: DC, 0.25 mA max., Von = 0.7 V DC,  Voff = 5.4V DC
Certifications: CE Mark
Environmental
Humidity Limits: 5 – 95% RH
Shock, Operating: 30 g, halve-sine, 11mSec pulse (tested in accordance with IEC-60068-2-27)
Vibration, Sinusoidal, Operating: 2g peak acceleration at 5-500 Hz (tested in accordance with IEC-60068-Vibration, Random, Operating: 6g rms acceleration at 5 to 2000 Hz (tested in accordance with IEC-60068-2-64)
Mounting
2” pipe mount with bracket, 316SS, for horizontal or vertical orientation mountings. Includes 2” U-bolts and hardware (zinc plated CS).
Standard bracket accommodates pipe mount or surface mounting
Standard Accessories
P/N Z1065        NIST Certificate with data
P/N Z9A683-1  1/8” NPT(M) x ¼” NPT(F) adapter (1 each for AI, CI and GI models), 316L SS
P/N Z9A683-2  1/8” NPT(M) x ¼” NPT(F) adapters (2 each for DI models), 316L SS
P/N Z9P120     Mounting bracket, 316 SS
P/N Z9A64       Mounting hardware kit, zinc plated CS, U-bolts (2 ea.), nuts, washers
P/N Z9R86       User’s Manual
Optional Accessories, Certifications and Tests
P/N Z1089         3-valve equalizing manifold kit, 316L SS, c/w pre-bent tubing & tube fittings
P/N Z9P130       Material Certification
P/N ZA33559    Hydrostatic Pressure Test
P/N Z1077         Tag, wired SS

关系电話
0731-84284278
线下信息
观注9九游
TOP
你们好,欢迎大家访问共享AG九游会集团
想进一步推动一个脚印知晓9九游 的成品和细则?

9九游 7*24小时为您服务!

电话咨询:0731-84284278

填写信息您的要,9九游 将快速与您连接
加强制度建设您的信息查询,AG九游会集团专业团队协作为您作为服务的!

请选择您要填写的表单类型 *

获利设备来报价
获得设计详细信息
注册技木功能

公司名称 *

姓名 *

手机号 *

邮箱

需求描述 *

验证码 *

上海管业有限公司 | 东莞市体育用品有限公司 | 深圳开关电源公司 |